Dane techniczne:
Image Device:
Type 1/2 (diag 8mm) progressive scan SONY IT CCD, ICX 414
Effective Picture Elements
656 (H) x 492 (V)
Picture Size
656 (H) x 492 (V)
Cell Size:
9.9 µm x 9.9 µm
Resolution Depth:
8 bit / 14 bit (16 bit in High SNR mode)
Lens Mount:
C-Mount / CS-Mount
Digital Interface:
IEEE 1394b (S 800 daisy chain)
Transfer Rate:
100, 200, 400, 800 Mbit/s
Frame Rates
up to 84 fps (full frames)
Gain Control
Manual: 0-24 db; Auto Gain
Shutter Speed:
30 µs - 67 s; Auto Shutter
External Trigger Shutter:
32 MB on board memory; deferred image transport; trigger delay; multi-shot; mirror image; several trigger modes; SIS (secure image signature); sequence mode; storable user sets
Smart Features:
LUT; shading correction; High SNR mode; white balance; color interpolation (debayering); local color anti aliasing; hue; saturation; sub-sampling; 2x - 8x binning or sub sampling; seperate reference AOI for auto features
Options:
angled heads; cable tails; optical filters; board level version; peltier cooled device; medical design on request
Pełna dokumentacja techniczna
Wyłącznym dystrybutorem kamery w Polsce jest firma Parameter
|